Key Specifications and Technical Details of Circuit Breaker iC60N C 20A 1P Schneider Electric A9F79120
The Circuit Breaker iC60N C 20A 1P from Schneider Electric (model number A9F79120) is a reliable compact protective device designed for low-voltage electrical installations. Engineered using the latest technologies, it offers superior performance and safety in residential, commercial, and light industrial setups.
- Rated Current: 20 Amperes (A)
- Poles: Single Pole (1P)
- Tripping Curve Type: C (suitable for general use with moderate inrush currents)
- Breaking Capacity: Up to 6kA at 230/400V AC
- Voltage Rating: 230/400 VAC
- Mounting: DIN rail 35 mm (standard mounting rail)
- Standards Compliance: IEC/EN 60898-1
- Dimensions: Compact — 12 mm width for efficient panel usage
These features make the iC60N a trusted choice for circuit protection, providing fast disconnection in overcurrent conditions and safeguarding electrical circuits effectively.
Top Use Cases for Circuit Breaker iC60N C 20A 1P Schneider Electric A9F79120: Practical Applications
The versatility of the iC60N C 20A 1P circuit breaker lends itself well to various electrical applications:
- Residential Electrical Panels: Protects household circuits including lighting and outlet circuits from overloads and short circuits.
- Commercial Buildings: Suitable for small to medium-sized businesses to maintain safety and comply with electrical codes.
- Industrial Automation: Protects control circuits and auxiliary power lines in automated machinery where precise overcurrent protection is critical.
- Renewable Energy Systems: Often used in solar panel inverters and installations as a reliable protective device.
The combination of rated current and single-pole design makes it especially practical for isolated circuit protection where space and safety are priorities.
How to Set Up and Configure Circuit Breaker iC60N C 20A 1P Schneider Electric A9F79120: Step-by-Step Instructions
Installing the iC60N C 20A 1P is straightforward, but requires adherence to electrical safety guidelines and standards. Follow these steps:
- Power Off: Ensure the main power supply is completely switched off before installation.
- Mounting: Attach the breaker onto a 35 mm DIN rail by hooking the back clip, applying firm pressure until it clicks into place.
- Wiring: Connect the line (input) wire to the upper terminal and the load (output) wire to the lower terminal. Use appropriate torque settings specified in the product datasheet, typically around 2.5 Nm.
- Check Connections: Verify wiring polarity and ensure terminals are tightened securely to avoid loose connections.
- Test the Breaker: Turn on the main power and manually toggle the breaker switch to ensure proper mechanical operation.
- Configure Settings (if applicable): While the iC60N C 20A 1P is ready-to-use, verify trip curve requirements match your application – type C curve for moderate inrush loads such as motors or lighting.
Following these steps ensures safe and efficient operation right from the start.
Advantages of Circuit Breaker iC60N C 20A 1P Schneider Electric A9F79120 Compared to Similar Models
Choosing Schneider Electric’s iC60N C 20A 1P offers several benefits over competing models:
- Enhanced Safety: Rigorous compliance with IEC standards guarantees reliable circuit interruption under fault conditions.
- Compact Design: At just 12 mm width, it saves precious panel space without sacrificing performance.
- Robust Durability: High-quality components built to withstand mechanical and electrical stress for optimum lifetime.
- Easy Integration: Compatible with a wide range of Schneider Electric products and accessories, enabling seamless system expansions.
- Accurate Trip Curves: Type C curve reduces nuisance tripping while providing precise overload protection for general-purpose circuits.
- Global Support: Schneider Electric’s worldwide presence assures you of readily available technical assistance and spare parts.
These attributes combine to offer an overall superior user experience and operational reliability.
Maintenance Tips to Extend the Lifespan of Circuit Breaker iC60N C 20A 1P Schneider Electric A9F79120
Regular maintenance of your circuit breaker ensures optimal safety and functionality over time. Here are practical tips:
- Routine Inspections: Check the breaker visually every 6 months for signs of wear, discoloration, or damage.
- Mechanical Operation Test: Toggle the breaker switch periodically to verify smooth operation.
- Cleaning: Keep terminals and contacts free from dust and corrosion. Use a dry, lint-free cloth; avoid liquids.
- Tighten Connections: Ensure terminal screws remain tight to prevent arcing or overheating.
- Load Monitoring: Avoid exceeding rated current to prevent premature tripping or damage.
- Professional Testing: Engage qualified electricians every 1-2 years for insulation resistance and trip test checks.
Proper upkeep not only improves safety but also maximizes the device’s lifespan.
How to Purchase Circuit Breaker iC60N C 20A 1P Schneider Electric A9F79120 through Global Vendor Network (GVN)
Acquiring the iC60N C 20A 1P circuit breaker through Global Vendor Network (GVN) is a simplified process designed to save you time and ensure product authenticity:
- Visit GVN’s Website: Navigate to the contact or inquiry section.
- Fill Out the Contact Form: Provide your company details, contact information, and specify the product model
A9F79120clearly. - Specify Quantity: Indicate the number of breakers you wish to purchase and any additional Schneider Electric products if required.
- Submit the Request: Review your details and send the inquiry. GVN’s sales team will get back promptly to confirm pricing, availability, and delivery timelines.
- Consultation: You can request technical support or customized solutions if needed during the communication process.
Buying with GVN assures you benefit from competitive pricing, genuine Schneider Electric components, and reliable logistics support.